High-sensitivity troponin testing at the point of care for the diagnosis of myocardial infarction: a prospective emergency department clinical evaluation

פוסט זה זמין גם ב: עברית

 Jemima May Curran1,   Aleksandra Mergo2,   Sarah White1,

Bernard L Croal3,   Jamie G Cooper1

Correspondence to Dr Jemima May Curran, Emergency Department, Aberdeen Royal Infirmary, Aberdeen, UK; jemima.curran2@nhs.scot

In the ED, laboratory high-sensitivity cardiac troponin (hs-cTn) tests facilitate ‘rule-out’ of myocardial infarction (MI).1 Contemporary point-of-care (POC) troponin tests have inferior analytical sensitivity,2 preventing rapid ‘rule-out’ strategies in near-patient settings. The new Siemens Atellica VTLi POC test meets hs-cTn criteria.3

Between June and September 2022, adult ED patients (≥16 years) with symptoms suspicious for MI and no ST-segment elevation on ECG were eligible for inclusion if staff trained on the POC instrument were available. Simultaneously, blood was taken for near-patient testing with the VTLi POC hs-cTnI assay (limit of detection (LOD) of 1.2 ng/L, sex-specific 99th percentile upper reference limits (URLs) of 18 ng/L (female) and 27 ng/L (male), and an optimised ‘rule-out’ threshold of <4 ng/L)3 and for laboratory testing with the Abbott Alinity hs-cTnI assay (LOD of 1.6 ng/L, URLs of 16 ng/L (female) and 34 ng/L (male), and an optimised ‘rule-out’ threshold of <5 ng/L),4 the standard-of-care assay for this evaluation. Patients with no result for either assay or who presented ≤2 hours from symptom onset were excluded and POC results were not available to clinicians.

The end-point was an index presentation type 1 MI or cardiac death, independently adjudicated by two investigators (blinded to POC results) according to the fourth universal definition of MI. …

השארת תגובה

חייבים להתחבר כדי להגיב.

גלילה לראש העמוד
Open chat
Scan the code
האיגוד הישראלי לרפואהה דחופה
שלום, קשר ישיר עם ההנהלת האתר איך אפשר לעזור?

Direct contact with the website management
How can we help?
דילוג לתוכן